The spacers should be of a projection type that has a minimum number of projections around the circumference that total the number of diameter inches. For example: 8" pipe should have a minimum of 8 projections and 18" pipe should have a minimum of 18 projections.

Spacing between spacer rings (span) should be calculated based on the actual installed load (weight of pipe filled with liquid) but should not exceed 10 feet / 3 meters. Refer to the tables in the current Raci Brochure and website for the load carrying capacity of each type of Raci spacer used.

Spacer should also have a minimum height that clears the pipe bell or as otherwise indicated on the plans.

Casing spacers should be projection type – non metallic spacers constructed of preformed sections of high-density polyethylene. Spacers should be ISO 9001:2000 certified for strength and quality.

Casing spacers should be installed using double backed tape provided with the spacers in order to fasten them tightly to the carrier pipe.

Typical Road Crossing